The MSR MiniWorks removes protozoa (including Giardia),
bacteria, some chemicals and many pesticides. MSR's Marathon
ceramic offers extended longevity and quick, easy cleaning, making
the MiniWorks effective, long lasting and easy to use.
Read and follow all instructions and warnings in this
manual before using the MiniWorks. (Version 1.2)
Relief Valve Assembly
If the Handle feels limp on the push stroke, debris may be caught in
the Relief Valve or the Inlet Valve Ball is missing. Unscrew the Inlet
Hose Barb from the Pump Head. Rinse the Relief Valve Poppet,
Spring and Ball. Reassemble.
Limited Warranty
The MiniWorks has a three year limited warranty. Should this product
fail during the three year warranty period, return it to one of our autho-
rized repair facilities. We will repair it or replace it at our option, free of
charge. Repairs due to improper use or care, negligence, product modifica-
tion, or accident are not covered under this warranty agreement, but will
be performed at a nominal charge on request.
This warranty applies only to the original purchaser. Proof of purchase is
required. Products purchased from an independent dealer should be
returned to the dealer for forwarding to MSR. Shipping cost to MSR is the
responsibility of the purchaser. Return postage will be paid by MSR.
EXCEPT AS PROVIDED HEREIN, MSR MAKES NO WARRANTIES,
EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE. MSR SHALL NOT BE LIABLE FOR ANY
CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER.
This warranty gives you specific legal rights. You may also have other
rights which vary state to state. Some states do not allow the exclusion or
limitation of incidental or consequential damages, or limitation or
exclusion of implied warranties, so the above exclusion and limitation
may not apply to you.
Patented
Germany: Patent No. M9008212 South Korea: Design Patent No. 126697
Taiwan: Patent No. ND-28287 United States: Patent No. D321,550 / 5,266,196 / 5,330,640
Australia: Design Patent No. 114171 United States: Patent No. 5,487,833 / 5,558,762 / 5,656,220
Japan: Registered Design No. 895427 United Kingdom: GB Reg. Design No. 2011749
Other Patents Pending
Piston O-Ring
If the Handle drags when pumping, lubricate the Piston O-Ring. Pull
out the Pump Head Pin and Bushing, then remove the Handle. Put a
light film of food-grade lubricant (MSR Silicone Lubricant, lip balm or
petroleum jelly) on the Piston O-Ring. Reassemble. If water leaks
from the Piston seal, replace the O-Ring.
Relief Valve Poppet
Inlet Hose Barb
Pump Head
Inlet Valve Ball
Relief Valve Spring
Inlet Barb O-Ring
Killing Viruses
Viruses need enough contact time with iodine to be effective. It is
difficult to achieve this contact time with the fast flow rates that
many portable water filters offer. To kill viruses, MSR recommends
pretreating the water with iodine (follow manufacturer’s instructions),
then filter the treated water through the MiniWorks. The carbon core
of the Marathon Cartridge will remove the iodine taste and odor.
Troubleshooting
If water flows slowly, the filter seems clogged, or the
pump stroke feels different than normal and:
Handle Is Hard to Push
Clean the Marathon Ceramic with the Pad (See "Marathon Cartridge").
Lubricate dry Piston O-Ring (See "Piston O-Ring").
Handle Feels Limp / No Resistance When Pumping
Clean under the Umbrella Valve. If debris is under the Valve, the Inlet
Foam is not effectively installed. Clean and reinstall the Inlet Foam.
Replace the Umbrella Valve if it is torn or damaged.
(1)
Missing Inlet Valve Ball (in the Relief Valve Assembly).
(1)
Hole in the Inlet Hose. Remove damaged section or replace it.
(1)
Damaged Inlet Barb O-Ring. Order a replacement O-Ring from MSR.
Handle Is Hard to Pull
Clean the Inlet Foam (See "Inlet Foam"). To prevent clogging, keep the
Hose above the bottom sediments using the Inlet Float.
Make sure the Inlet Hose is not kinked or blocked.
Squeaky / Noisy When Pumping
The Relief Valve is blowing due to filter clogging (See "Marathon
Cartridge") or pumping too fast. Pump the Handle no faster than 1
stroke per second.
Pump stroke is normal, but water flows slowly
Pumping too fast. Pump no faster than 1 stroke per second. Pumping too
quickly increases the number of pump strokes without increasing water
flow because the Relief Valve reverses the water back out the Inlet Hose.
Air bubble in the Pump Head. To remove the air, turn the filter upside
down while keeping the Hose under water. Pump the Handle 3 - 5 strokes
until the air is purged, then return the filter upright for regular pumping.
To prevent air from entering, keep the Inlet Cage under water. Air in the
Pump Head may also be caused by debris in the Valves (See "Umbrella
Valve" and "Relief Valve Assembly").
(1)
Replacement parts are in the WaterWorks & MiniWorks Maintenance Kit,
Marathon Replacement Kit, and the Inlet Hose Kit. If you need help
maintaining your filter, troubleshooting problems, or replacing parts,
contact your nearest MSR retail dealer or MSR Customer Service.
For more product or safety information, contact MSR
Customer Service. MSR will also service your filter or
provide replacement instructions on request.
Mountain Safety Research FAX: (206) 224-6492
P.O. Box 24547 (206) 624-7048
Seattle, WA 98124 USA 1-800-877-9677
Pump Head Bushing
Piston O-Ring
Pump Head Pin
Piston Pin
Piston Bushing
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - MiniWorks

MSR® MiniWorks TMWater FilterThe MSR MiniWorks removes protozoa (including Giardia),bacteria, some chemicals and many pesticides. MSR's Marathon

Seite 2 - Umbrella Valve

When Do I Clean the Marathon Cartridge?•If little or no water flows when pumping. Clean if it takes morethan 2 ˚ - 3 minutes or 125 - 150 strokes to f

Kommentare zu diesen Handbüchern

Keine Kommentare